Energy Saving and Rapid Cooling
The Dual Inverter™ Compressor constantly adjusts its speed to maintain the desired temperature levels. In this way, the Dual Inverter™ Compressor saves more energy than a conventional compressor. Expelling the air at a greater distance and in less time.
Gold Fin
The outdoor air conditioning unit is exposed to pollution and pollutants that can corrode it causing failures and reducing the useful life of the equipment. LG's Gold Fin function protects the air conditioner thanks to the anti-corrosion coating that repels moisture and increases the life of the equipment.
ANTICORROSION
An anti-corrosion layer on aluminum surface for durability. That way the performance of the unit will be practically the same as when acquiring it.
SIMPLE AND LIGHTWEIGHT DESIGN WITH HIDDEN DISPLAY
The slim and modern design of the LG air conditioner makes it easy to install and clean with the EZ sliding filter. In addition, the hidden screen is perfect for checking the display of power consumption
HIGH VOLTAGE INSURANCE
LG PCB (Power Circuit Board) has been upgraded to increase its ability to withstand voltage variations, thus ensuring safety against surges, while strengthening the durability of the air conditioner.
Quiet Operation
LG's air conditioners operate at low sound levels, thanks to its skewed fan and Dual Inverter™ Compressor, eliminate unnecessary noise and allow smooth operation.
QUICK AND EASY INSTALLATION
LG air conditioners are designed for easier and more efficient installation, no matter the environment and the number of people involved in the installation process. By reducing the labor and time needed for installation, it is now possible to install more airs in more homes in a shorter period of time.
Filters out unwanted contaminants
LG's filtration system is designed to capture dust particles larger than 10μm while removing allergens from the air, such as dust mites, for a cleaner and healthier environment.
SPECIFICATIONS
CAPACITY
-
- Cooling - Min ~ Rated ~ Max (kW) - 0.90 / 3.52 / 4.04
- Cooling - Min ~ Rated ~ Max (Btu/h) - 3070.00 / 12000.00 / 13780.00
-
- Heating - Min ~ Rated ~ Max (kW) - 0.90 / 3.52 / 4.04
- Heating - Min ~ Rated ~ Max (Btu/h) - 3070.00 / 12000.00 / 13780.00
-
- Maximum heating OD 19 / 17 ºF DB / WB (Btu / h) - 9,640 (80%)
POWER INPUT
-
- Cooling - Min ~ Rated ~ Max (W) - 200 / 1142 / 1400
- Heating - Min ~ Rated ~ Max (W) - 195 / 1000 / 1200
-
- Maximum Heating(@ID 70ºF DB) - OD 19/17ºF DB/WB(W) - 1470
RUNNING CURRENT
-
- Cooling - Min ~ Rated ~ Max (A) - 1.1 / 5.2 / 6
- Heating - Min ~ Rated ~ Max (A) - 1.1 / 4.7 / 7
EER
-
- EER (W/W) - 3.08
- EER (Btu/hW) - 10.51
SEER
-
- SEER - 19
COP
-
- COP (W/W) - 3.52
- COP (Btu/hW) - 12
HSPF
-
- HSPF - IV. / V. ¹ - 9.5 / 8.3
ENERGY STAR
-
- Energy Star - No
TAX CREDIT
-
- Tax Credit - No
POWER SUPPLY
-
- Power supply (Ø, V, Hz) - 1, 208/230, 60
AVAILABLE VOLTAGE RANGE
-
- Available Voltage Range - Available Voltage Range (V) - 187~253
POWER FACTOR
-
- Power factor - Cooling / Heating (%) - 97 / 97
MOISTURE REMOVAL
-
- Moisture removal (pts/h (l/h)) - 2.7 (1.3)
INTERIOR
-
- Airflow Rate (Cooling) - Max/H/M/L(㎥/min) - 13.0 / 10.0 / 7.5 / 4.2
- Airflow rate (cooling) - Max / H / M / L (CFM) - 459 / 353 / 264 / 148
-
- Airflow Rate (Heating) - Max/H/M/L(㎥/min) - 13.0 / 10.0 / 7.2 / 5.6
- Airflow rate (heating) - Max / H / M / L (CFM) - 459 / 353 / 254 / 198
-
- Sound pressure level (cooling) - H / M / L / SL (dB(A)) - - / 42 / 36 / 28 / 21
- Sound pressure level (heating) - H / M / L (dB(A)) - - / 42 / 36 / 28
-
- Dimensions (W × × D) - Net (mm) - 837 × 308 × 189
- Dimensions (W × H × D) - Net (in.) - 32-15/16 × 12-1/8 × 7-7/16
-
- Dimensions (W × × D) - Shipping (mm) - 897 × 390 × 254
- Dimensions (W × H × Pr) - Shipping (in.) - 35-5/16 × 15-11/32 × 10
-
- Weight - Net (lb. (kg)) - 19.2 (8.7)
- Weight - Shipping (lb. (kg)) - 25.4 (11.5)
-
- Disconnect switch (A) - 15
- External color code - Munsell 7.5BG 10/2 (RAL 9016)
-
- Operating Range - Maximum Relative Humidity (%) - 78
OUTSIDE
-
- Airflow Range - Max (㎥/min) - 27
- Airflow Range - Max (CFM) - 953
-
- Sound pressure level (cooling) - Max (dB(A)) - 50
- Sound pressure level (heating) - Max (dB(A)) - 50
-
- Dimensions (W × × D) - Net (mm) - 717 × 495 × 230
- Dimensions (W × H × D) - Net (in.) - 28-1/4 × 19-1/2 × 9-1/16
-
- Dimensions (W × × D) - Shipping (mm) - 837 × 531 × 324
- Dimensions (W × × D) - Shipping (in.)) - 32-31/32 × 20-29/32 × 12-3/4
-
- Weight - Net (lb. (kg)) - 55.3 (25.1)
- Weight - Shipping (lb. (kg)) - 60 (27.2)
-
- Max. Fuse size (A) - 0
- External color code - Munsell 9.54Y 8.34/1.31 (RAL 9001)
-
- Operating Range - Cooling (°F(°C) DB) - 14~118.4 (-10~48)
- Operating Range - Heating (°F(°C) WB) - 14~65 (-10~18.3)
COMPRESSOR
-
- Guy - Twin Rotary
- Model - GST102MAA
-
- Engine type - Brushless DC Motor
- Type of oil - POE (RB68A) / Sun Oil or Jx Nippon, PVE (FVC68D) / IDEMITSU
-
- Oil load (cc) - 280
- Manufacturer / Country of origin - LG Electronics / China
FAN(INDOOR)
-
- Guy - Cross Flow Fan
- Motor output (W) - 30
FAN(OUTDOOR)
-
- Guy - Propeller Fan
- Engine type - BLDC
-
- Motor output (W) - 43
- Motor insulation - Class E
-
- Engine Housing/Ingress Protection - TEAO / IPX4
MINIMUM CIRCUIT AMPACITY
-
- Minimum circuit ampacity (A) - 10
CIRCUIT BREAKER
-
- Circuit breaker (A) - 15
POWER CORD
-
- Power Cord (AWG No. × (㎟)) - 3 × 14 (1.5)
POWER SUPPLY TO THE UNIT
-
- Power supply to the unit - Outdoor
POWER AND TRANSMISSION CABLE
-
- Power and Transmission Cable (No. × AWG) - 4 × 18 (1)
PIPE
-
- Size - Liquid (in. (mm)) - Ø 1/4 (Ø 6.35)
- Size - Gas (in. (mm)) - Ø 3/8 (Ø 9.52)
-
- Method of connections - Indoor / Outdoor - Flared / Flared
DRAIN HOSE SIZE
-
- Method of connections - O.D, I.D (in. (mm)) - 27/32, 5/8 (21.5, 16.0)
BETWEEN INTERIOR AND EXTERIOR
-
- Pipe length - Min / Standard / Max (ft. (m)) - 9.8 / 24.6 / 49.2
- (3 / 7.5 / 15)
- Pipe length - Chargeless (ft. (m)) - 24.6 (7.5)
-
- Max. Elevation difference (ft. (m)) - 23 (7)
REFRIGERANT
-
- Refrigerant - Type - R410A
- Refrigerant - Pre Charge (oz. (g)) - 30 (850)
-
- Refrigerant - Additional Charge (oz./ft. (g/m)) - 0.22 (20)
- Refrigerant - Control - Electronic Expansion Valve
DEFROSTING METHOD
-
- Defrosting method - Reverse Cycle
TOOL CODE(CHASSIS)
-
- Tool code (chassis) - Indoor + Outdoor - SJ + UA3
Wishlist